UC2000-30GM-IUR2-V15 Ultrasonic sensor
Technical Data
General specifications
Sensing range 80 ... 2000 mm
Adjustment range 120 ... 2000 mm
Dead band 0 ... 80 mm
Standard target plate 100 mm x 100 mm
Transducer frequency approx. 180 kHz
Response delay 65 ms minimum
195 ms factory setting
Indicators/operating means
LED green solid: Power-on
flashing: Standby mode or program function object detected
LED yellow 1 solid: object in evaluation range
flashing: program function
LED yellow 2 solid: object in detection range
flashing: program function